  • 產(chǎn)品名稱:Vermason 222547校準(zhǔn)器

  • 產(chǎn)品型號(hào):用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車
簡(jiǎn)單介紹:
Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565,Vermason(DESCO子品牌)
詳情介紹:

Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester
用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀
適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565
Vermason(DESCO子品牌)

Operation
The Tester Calibration Unit was specifically designedfor use in calibration of Vermason brand equipment.The following procedures will not cover adjustment of
the test equipment. For detailed information regardingadjustment of specific Vermason brand testers, pleasecontact Desco Europe Customer Service.

Frequency of recalibration should be based on thecritical nature of those ESD sensitive items handled andthe risk of failure for the ESD protective equipment andmaterials. In general, we recommend that calibration be
performed annually.

Testing the Compact Tester
WRIST STRAP CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the wrist strap stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unitand repeat the test. The tester should indicate aFAIL HIGH condition.

FOOTWEAR CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the 10 mm footwear stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unit andrepeat the test. The tester should indicate aFAIL HIGH condition

姓名:
電話:
您的需求:
 
蜜桃comaaa| 99视频在线精品免费观看6| 丝袜无码一区二区三区| 97在线视频观看| 久草成人| 色久优优| 免费亚洲婷婷| 人妻精品一区二区三区| 女人18片毛片90分钟| 攻演戏时真进去了h| 一本色道久久综合亚洲精品酒店| 人妻体内射精一区二区三区| 中文字幕一区二区三区四区| 日韩av大片| 一区二区三区黄色| 亚洲国产精品欧美久久| old色老头做受| 日韩成人精品| 99精产国| 久久视频网| 91精品国产高清一区二区三密臀| 久久久国产成人噜噜噜噜| 欧洲亚洲一区| 中文字幕一二区| 亚洲一线产区二线产区区| 79久久精品熟女人妻| 欧美日一区二区| 日韩黄色片| sese网站| 亚洲成a人| 人妻中文字幕一区二区三区 | 国产精品成人免费视频网站| 国产玖玖玖九九精品视频靠爱| 亚洲爆乳成人无码AAA片漫画| 台湾成人网| 国产靠逼视频| 国产激情综合五月久久| 天堂综合网| 天天躁狠狠躁狠狠躁夜夜躁68| 国产精品国产精品| 黄色av网址|